120V hard wiring installation

4.5.1 NEFL32/42/50/60/74/100CHD 120V hardwiring
WARNING
!
Turn off the appliance completely and let cool before servicing. Only a qualifi ed service person should service
and repair this electric appliance.
If it is necessary to hard wire this appliance, a qualified electrician must remove the cord connection and wire the
appliance directly to the household wiring. The wire and power supply breaker must be rated for 120V minimum
15 amps.
This appliance must be electrically connected and grounded
in accordance with local codes if hard wired. In the absence
of local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the current ANSI/NFPA 70
National Electrical Code in the United States.
Before hardwiring the appliance, remove the junction box
control cover by removing the fasteners as shown.
note:
There are 6 wires from the appliance junction that connect to 120V power supply (breaker panel): 1 white
(neutral), 2 yellow (heater & neutral), 1 black (power L1), and 1 green (ground). Do NOT connect red wire to
power supply (breaker panel).
16
W415-2212 / C / 03.06.18
(N)
Jumper
WHITE (N)
Jumper
YELLOW (N1)
YELLOW (N2)
(L1)
BLACK (L1)
RED (L2)
(G)
GREEN (G)
Use 2 wire jumpers
to connect N to N1
and N2.