Hard Wiring Installation - Napoleon Cinema Serie Manuel D'installation Et D'opération

Masquer les pouces Voir aussi pour Cinema Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.3.1

hard wiring installation

WARNING
!
Turn off the appliance completely and let cool before servicing. Only a qualified service person should service
and repair this electric appliance.
HARD WIRING CONNECTION
If it is necessary to hard wire this appliance, a qualified electrician must remove the cord connection, and wire the
appliance directly to the household wiring. The wire and power supply breaker must rated for 120V minimum 15
Amps.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired. In the
absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the current
ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
NOTE: There are 3 wires from the fireplace junction; white (neutral), black (power L1) and green
(ground) that connect to 120V power supply (breaker panel), see below.
* NEFB29HG ILLUSTRATED
Remove the securing screw from the electrical cover plate, located on the right hand side of the fireplace.
A.
Add an electrical box connector and feed the supply wires through the 7/8" (22mm) hole.
B.
Separate the black, white and green wires that have the wire nuts on them.
C.
Remove the wire nuts and secure the black wire (power L1) to the black (power L1) lead of the power
D.
supply. Connect the white wire from the unit to the white (neutral) wire from the power supply. Connect
the green wire to the ground wire.
Resecure the cover plate.
E.
WHITE
BLACK
GREEN
installation
White, Green and
Black wires:
Connect to 120V
power supply.
WHITE
BLACK
GREEN
W415-1662 / C / 07.20.20
EN
11

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Cinema nefb24hgCinema nefb27hgCinema nefb29hg

Table des Matières