3.3.6
240V HARD WIRING INSTALLATION
EN
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED
240V HARD WIRING CONNECTION
If it is necessary to hard wire this appliance, a qualifi ed electrician must remove the cord connection, and wire
the appliance directly to the household wiring. The wire and double-pole power supply breaker must rated for
240V minimum 15 Amps, maximum 20 Amps.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired.
In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the
current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
NOTE: There are 4 wires from the fi replace junction; white (neutral), black (power L1), Red (Power L2)
and green (ground) that connect to 240V double-pole power supply (breaker panel).
W415-2165 / E / 02.23.17
SERVICE PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
Voltage Selector Switch
WHITE
WHITE (N)
BLACK
BLACK (L1)
RED (L2)
GREEN (G)
RED
GREEN
WARNING
!
Wire Nut
WHITE
BLACK
RED
GREEN
White, Black, Red and
Green wires:
Connect to 240V
power supply.
WHITE (N)
BLACK (L1)
RED (L2)
GREEN (G)