Burg Wächter TSE 5000 Série Instructions De Montage Et Mode D'emploi page 29

Système électronique de fermeture
Masquer les pouces Voir aussi pour TSE 5000 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• Priority
In case the door cannot be opened after several attempts with the E-KEY, the
priority of the door can be increased by this function. Conversely, it might be
advisable in such a case to reduce the priority of doors in a direct vicinity.
• Reorganize
The use of this function is recommended when several users have been
deleted.
– Activate the keypad using the
– Then press FUNC, the "Code Change" menu is displayed
– Scroll using the 2 key until reaching the Administrator menu
– Confirm with
– Scroll using the 2 key until reaching the "Admin. TSE Setup" menu item
– Confirm with
– Confirm with
– Enter the administrator code in order to acquire the authorisation
for programming "Reorganisation in progress" is displayedt
• Register
After a replacement of the cylinder or the keypad, the two units have to be
newly aligned, so that they can resume communication..
Registration of a keypad
– Activate the keypad using the
– Then press FUNC, the "Code Change" menu is displayed
– Scroll using the 1 or 2 keys until reaching the Administrator menu
– Confirm with
– Now scroll using the 1 or 2 keys until reaching the Admin. TSE Setup menu
– Confirm with
– Now scroll using 1 or 2 keys until reaching the Admin.
TSE Setup Register menu
– Confirm with
– Enter the administrator code in order to acquire the authorisation
for programming
– "Data has been saved" is displayed after a successful registration
Attention: Make sure that no other powered TSE unit is placed within a
direct reach of the device when registering a new keypad of a new cylinder,
as such unit could mistakenly be addressed instead of the intended one.
When in doubt, disconnect such units from power.
• Energy-saving mode
With the setting of the power saving mode, an optimal power consumption
of the units is ensured. The power saving mode can be switched on or off.
If the mode is turned on, no programming of the unit can be performed via
the PC software.
By default upon delivery the power saving mode is turned on, thus
for a possible programming via the PC software it has to be turned
off.