TSE E-KEY user instructions
The E-KEY is intended as radio transmitter for releasing the cylinder. The
E-KEY can be subsequently programmed by means of a keypad or of a
TSE software. The radio range of the E-KEY is up to 3 m. The principle of
its function is similar to that of a car locking system. The cylinder can be
controlled when the button is pressed once.
Functions of E-KEY
Door opening:
– Press 1 xbriefly, green LED flashes
– Automatic function (only together with a keypad) Hold the button
pressed for 6 seconds, green LED flashes briefly 2 x in a row
– Permanent mode (only together with optional software) Press the button
2 x, the green LED flashes always 2 xin a row per pressed button
In the automatic mode the door can be opened by pressing the
on the keypad. For this purpose, the E-KEY must be within the radio range.
This function will be deactivated automatically after a period of 15 minutes.
In the permanent mode, the door is unlocked for a period defined in the
software without the need for entry of a code. When entering an opening
code during this period, the permanent release will be deactivated.
Programming mode:
The programming mode has three purposes:
– Registration of an E-KEY by means of a keypad or of the TSE software
– Synchronization of the radio signal set up in the E-KEY with the
channel set in the lock
– Searching for the E-KEY within the TSE software
Programming E-KEY
When programming the EKEY for the first time, please press the button
once (green LED flashes) when being required to do so by the keypad or
by the software. When programming the E-KEY later on, please keep the
button pressed for a period of 10 seconds, until the green LED flashes three
times in a row. Then release the button.
Remarks:
In case the door opens with a delay of 3 to 7 seconds after the button on
the EKEY is pressed once, and the red LED flashes, the battery (CR2032)
in the E-KEY should be replaced immediately. In case the door opens with
a delay of 3 to 7 seconds after the button on the E-KEY is pressed once,
and the red LED does not flash, the batteries (2x 1.5V LR06 alkaline) in the
cylinder should be replaced. This applies also to the keypad, if installed.
ME
TSE PRIME
button