On button
Activation of the keypad for entry of an opening code.
Enter button
Selection of a menu item.
Function button
The function button provides for a variety of actions depending on the
actual status of the keypad. The display indicates, which function is active.
1) Entry into the menu for programming
When the "Func:M" symbol is displayed, the menu can be reached by
pressing the "Function" button. In the menu, the buttons "1" and "2"
can be used as a scroll function to navigate through its structure.
2) Deleting an entry action
When the "Func:C" symbol is displayed, the last entry can be cancelled
by pressing the "Function" button.
3) Entry into the previous programming level / Back
When you are in the menu, the symbol "Func:<" is displayed. By pressing
the "Function" button, you return into the menu structure on the next
higher level.
Battery status indication
The display indicates the battery statuses of the cylinder unit and the
keypad unit. The indication on the display concerns the batteries with the
lowest status. In case a battery is empty, the display indicates as follows:
Replace the battery inside the keypad or replace the battery inside
the knob.
When the battery has been replaced and then the opening code has been
entered twice, the actually lowest battery status is displayed. When only a
single battery set is replaced, the display can still indicate an "incomplete"
status, despite the replacement. In case you do not replace the batteries
in spite of the replacement indication, you will have to enter the valid
opening code once more in order to open the door. At the same time,
the LED of the inner knob flashes 5 x5 times. You can still open the
door in this way approx. 50 times. Then it can only be opened using the
administrator code. Now the batteries must be replaced, otherwise the
door cannot be opened any more.
Fingerscan-Sensor
To open with or register the particular finger.
ME
TSE PRIME
Battery full
Battery empty
English | 23