Technical data
Blocking times
Display
Power supply for
keypad
Power supply for
cylinder
Permissible
ambient
conditions
Keypad protection
In case the temperature exceeds the specified range, a corresponding warning message is
*
indicated on the display. Provide for appropriate corrective action!
TSE Set 5022 FINGERSCAN
The electronic cylinder operates using a fingerscan. In addition, the cylinder
can be operated by entering the 6-digit numeric code, or also using the
optionally delivered TSE 5103 E-KEY.
In add. to that, you can also use the 6-digit numeric code, as well as
the TSE 5103. E-Key in order to control the cylinder.
Up to 24 fingers can be programmed using the keypad. The users are
created separately (USER XXX_FP). If a code and / or an E-KEY should
additionally be assigned to a user, it needs to be created separately.
Attention! The fingerscanner must not be cleaned with detergents.
Please use a slightly moist cloth for this purpose.
TSE 5022 FINGERSCAN functions (standard)
– Total number of users: up to 48, out of which 24 can
be programmed with fingerscan
– One E-KEY can be assigned to each code user (except administrator)
– Also a code can be assigned to every E-KEY user
Optional locking media
– TSE 5103 E-KEY
Additional functions available using the optional TSE Software,
for example:
– User administration
– Time and calendar functions
– Assignment of authorisations
– History functions
Administrator code
– Factory set to 1-2-3-4-5-6 (please be sure to change it)
ME
TSE PRIME
After 3 x wrong code is entered 1 minute,
then always 3 minutes
Adjustable to 12 languages
2 xMIGNON LR6 AA ALKALINE
2 xMIGNON LR6 AA ALKALINE
-15 °C / +50 °C / up to 93 %
rel. air humidity (noncondensing)
Allowed temperature range: -20 °C / +50 °C
*
As a result of extreme temperature changes, the
display can react slowly or darken.
IP65