Installation

Models Prepped for Card Reader

The machine is shipped from the factory with the
Electronic Control Diagnostic Harness Assembly
unplugged. To avoid unauthorized manual
programming or vending, perform the following steps.
1. Open control panel. Refer to Figure 22.
2. Locate diagnostic harness on electronic control.
3. Plug connectors for "white/black" wire and "red/
blue" wire together.
1
Control Panel
Figure 22
18
1
FLW6R
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Additional Washer Security

(Coin Models Only)
Located on the service door of the washer is a flat
Phillips head screw. During shipment, this screw is
used to attach the service door to the meter case. For
additional security, this screw can be reinstalled inside
the control hood of your washer. Refer to instructions
below for installation.
Tamper-resistant screws also can be installed for
additional security. Tamper-resistant screws, bits and
bit holder are available as optional equipment at extra
cost. Part numbers are:
 Bit (No. 8 screws) Part No. 281P4
 Bit (No. 12 screws) Part No. 282P4
 Bit Holder (3/8 drive) Part No. 24161
 Control panel tamper-resistant screw Part No.
35528
 Front panel tamper-resistant screw Part No.
35527
The following list is the procedure required to install
the Phillips head screw and tamper-resistant screws:
WARNING
Any disassembly requiring the use of
tools must be performed by a suitably
qualified service person.
To reduce the risk of electric shock, fire,
explosion, serious injury or death:
• Disconnect electric power to the washer
before servicing.
• Never start the washer with any guards/
panels removed.
• Whenever ground wires are removed
during servicing, these ground wires
must be reconnected to ensure that the
washer is properly grounded.
1. Remove the Phillips head screw from service
door (refer to Figure 23).
2. Remove two screws holding control panel to
control hood.
W299
W003
201940

Publicité