2
1
120±12
V.A.C.
120±12
V.A.C.
Standard 120 Volt, 60 Hertz
3-Wire Effectively
Grounded Circuit
1
L1
2
Ground
3
Neutral Side
4
Round Grounding Prong
5
Neutral
Figure 10
WARNING
To reduce the risk of an electric shock or
fire, DO NOT use an extension cord or an
adapter to connect the washer to the
electric power source.
Grounding Instructions
The washer must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current.
The washer is equipped with a cord having an
equipment-grounding conductor and a three-prong
grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and
grounded in accordance with all local codes and
ordinances.
201940
3
0 V.A.C.
5
4
DRY2022N
W082
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
Improper connection of the equipment-
grounding conductor can result in a risk
of electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the washer is
properly grounded.
DO NOT modify the plug provided with the
washer – if it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
If the laundry room's electrical supply does not
meet the above specifications and/or if you are
not sure the laundry room has an effective
ground, have a qualified electrician or your local
electrical utility company check it and correct
any problems.
WARNING
Any disassembly requiring the use of
tools must be performed by a suitably
qualified service person.
Step 7: Add Water to the Washer
To prevent damage to pump, do not run washer before
adding at least one quart water to the tub. If the washer
is run before any water is added, the pump seal may
overheat, causing the pump to leak. Once installed, the
water retained in the drain system from the previous
cycle will provide sufficient cooling to prevent pump
seal damage.
NOTE: The agitator should not be removed except
for service. The washtub is designed to be self-
cleaning.
Figure 11
Installation
W327
W299
TLW2056N
TLW2056N
13