1.
INSTALLATION INSTRUCTIONS
Installation of the filter assembly below the water level of the pool is highly recommended. In the event that
the filter is installed above the pool water level, a check valve, accessible through a service hatch, must
be installed on the suction line.
•
Allow a surface area of 1200 mm x 1200 mm for the installation.
•
Position the control panel as close as possible to the multiport valve to facilitate manipulations.
•
To prevent vibrations, and any resonance effect, insert a sheet of soft rubber between the base of the
pump and the ground.
1.1
Standard installation
A - B :
Skimmer
C :
Main drain
D :
Vacuum point
E :
Return fitting
F :
Drain
16/48
2021/01 - Indice de révision : I - Code : 26690
VALVE
FILTER
(OPTION)
Ø 500
1''1/2
Ø 610 A
1''1/2
Ø 610 B
2''
Ø 760
2''
Ø 920
2''
D
A B C
A
B
C
802
503
800
417
840
612
915
418
840
612
930
418
985
762
1083
495
1111
923
1245
557
F
E
CONSTRUCTION & RÉNOVATION
D
E
476
477
493
576
638