3.
MULTIPORT VALVE FUNCTIONS (OPTION)
CAUTION
Never change the valve position while the pump is on, this could cause serious damage to the filter
and will cancel the guarantee.
CONSTRUCTION & RÉNOVATION
FILTRATION : The usual valve position. Water from the pump crosses the filter
from top to bottom and returns to the pool.
DRAIN : Water from the pump is routed directly to waste without passing through
the filter.
CLOSED :
No circulation is possible. Never run the pump while the valve is in
this position.
WASHING :
Water from the pump passes through the filter from the bottom to the
top and is then routed to waste taking with it all the impurities trapped in the filter.
CIRCULATION :
Water from the pump returns directly to the pool without passing
through the filter.
RINSE : Water from the pump passes through the filter from top to bottom and is
then routed to waste.
2021/01 - Indice de révision : I - Code : 26690
19/48