1.2.3 Prohibited Use
Other use than that described in chapter "Use as directed" is not intended and can lead to per-
sonnel injuries and equipment damage.
The system may not be used
with a machine that does not comply with appropriate national directives or standards,
for driving elevators,
in applications with continuous, operational short circuits to the external regen resistor
contacts.
in applications with any short circuits to the DC-Bus link contacts.
The use of the device in the following environments is also prohibited:
potentially explosive areas
environments with corrosive and/or electrically conductive acids, alkaline solutions, oils,
vapors, dusts
ships or offshore applications
Wiring the system with hybrid cables from other manufacturers than Kollmorgen is not
allowed. Changing Kollmorgen cables or connectors is not allowed.
1.2.4 Warning note labels
If these signs are damaged, they must be replaced immediately.
1.2.4.1 Notes placed on the product
shall comply with the local safety
In a system with supercapacitors, the waiting time for servicing can increase. Based on the
risk assessment, the user must attach additional warning labels in the control cabinet.
The minimum size of the
protective earthing conductor
regulations for high protectice
earthing conductor current.
MKD Product Safety Guide | 1 English
Residual Voltage
Wait 5 minutes after removing
power before servicing.
Kollmorgen | kdn.kollmorgen.com | September 2019