Control Module Removal - Napoleon Vector Série Manuel D'installation

Masquer les pouces Voir aussi pour Vector Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

maintenance
EN
D.
Disconnect the fl ex connector from the valve. Remove the valve wire connections, labeling each one to aid
with re-connection.
E.
Remove the screws from the valve bracket and remove the valve.
F.
Replace all components before returning the appliance to service.
G.
Check for gas leaks by brushing on a soap and water solution.

13.5 control module removal

A.
Remove the safety barrier and glass door, refer to the "safety barrier installation / removal" and "door
installation / removal" sections for details.
B.
Remove the two screws holding the control module in place, unplug and remove.
C.
Ensure to identify the wires plugged into the control module. It is critical that wire are reconnected to
the appropriate connectors.
D.
Replace and reinstall components.
64
W415-1709 / D / 06.14.19
CONTROL MODULE