Minimum Clearance To Combustible Enclosures - Napoleon Vector Série Manuel D'installation

Masquer les pouces Voir aussi pour Vector Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

rough framing - before appliance installation
EN

4.1.1 minimum clearance to combustible enclosures

single-sided
1" [25mm] minimum
all sides for sections
of vertical venting.
When passing through
a ceiling, use fi restop
spacer W500-0028
(not supplied)
0" to side standoffs
1/2" fi nishing fl ange
0" to bottom of the
appliance
Horizontal vent sections: A minimum clearance of 3" (76mm) on the top outside of the enclosure and 2" (51mm) on
the sides and bottom outside of the enclosure all around the vent pipe on all horizontal runs to combustibles is required.
Horizontal vent sections within enclosures require a minimum clearance of 6" (152mm) at the top of the vent pipe.
Vertical vent sections: A minimum of 1" (25mm) all around the vent pipe on all vertical runs to combustibles is required
except for clearances in appliances enclosures. Vertical vent sections within enclosures require a minimum clearance of
1" (25mm) around the vent pipe.
minimum clearance
Ref
LV38-1
L
note:
The LV series requires a minimum enclosure/ceiling height, as illustrated (dimension L), measured from the bottom of the
appliance. For temperature requirements, this area must be left unobstructed. Some venting confi gurations that require
more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and
combustibles.
26
W415-1709 / D / 06.14.19
L
LV50-2
73" (185.4cm)
note:
Shaded components (fi nish framing) must
be non-combustible materials.
3" [76mm] (minimum all sides
for sections of horizontal vent-
ing) outside of enclosure.
LV62
LV74
91" (231.1cm)
6" [152mm] minimum
(inside enclosure)
3" [76mm] top (outside
of enclosure)
2" [51mm] sides /
bottom (outside of en-
closure)
0" to non-combustible
fi nishing such as brick
and stone
When passing through
a wall, use fi restop
spacer W615-0162
(supplied with W010-
4178 fi restop spacer
assembly)
0" to back standoffs