Control Module Removal - Napoleon Vector Serie Manuel D'installation

Masquer les pouces Voir aussi pour Vector Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Disconnect the flex connector from the valve. Remove the valve wire connections, labeling each one to aid
D.
with re-connection.
Remove the screws from the valve bracket and remove the valve.
E.
Replace all components before returning the appliance to service.
F.
Check for gas leaks by brushing on a soap and water solution.
G.

13.5 control module removal

Remove the safety screen and glass door, refer to the "SAFETY SCREEN INSTALLATION /
A.
REMOVAL" & "DOOR INSTALLATION / REMOVAL" sections for details.
Remove the two screws holding the control module in place, unplug and remove.
B.
Ensure to identify the wires plugged into the control module. It is critical that wire are reconnected
C.
to the appropriate connectors.
D.
Replace and reinstall components.
CONTROL MODULE
maintenance
59