Minimum Framing Dimensions - Napoleon Vector Série Manuel D'installation

Masquer les pouces Voir aussi pour Vector Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.1

minimum framing dimensions

6" (15.2cm) min.
F
*E
minimum framing
LV38-1
*E
53 13/16" (136.7cm) 65 13/16" (167.2cm) 77 13/16" (197.6cm) 89 13/16" (228.1cm)
F
G
63 3/4" (162cm)
H
I
90 3/16" (229cm)
Horizontal vent sections: A minimum clearance of 3" (76mm) on the top outside of the enclosure and 2"
(51mm) on the sides and bottom outside of the enclosure all around the vent pipe on all horizontal runs to com-
bustibles is required. Horizontal vent sections within enclosures require a minimum clearance of 6"(152mm) at the
top of the vent pipe.
Vertical vent sections: A minimum of 1" (25mm) all around the vent pipe on all vertical runs to combustibles is
required except for clearances in appliances enclosures. Vertical vent sections within enclosures require a mini-
mum clearance of 1" (25mm) around the vent pipe.
*Single-sided model illustrated.
rough framing - before appliance installation
Do not put objects in front of the
appliance (minimum distance of 4 feet)
LV50-2
20 1/8" (51.1cm)
72 1/4" (183.5cm)
18 3/16" (46.2cm)
102 3/16" (259.5cm) 114 1/8" (289.9cm)
H
F
I
LV62
80 11/16" (205cm)
126 1/8" (320.4cm)
G
1" (2.54cm) min.
LV74
89 1/4" (226.6cm )
W415-1709 / D / 06.14.19
EN
25

Publicité

Chapitres

Table des Matières
loading

Table des Matières