6.5.1 Standby, Run and Autorun

On the Manager IQ Easy's main screen, press the "CMM IQ Easy" symbol. Press
generator in Run mode. On the main screen
Press
to put the generator back in Standby mode. If the "Autorun" parameter (Figure 10)
displays "Yes", the generator will automatically go to Run after starting up.
Figure 11.

6.5.2 Control mode

A CMM IQ Easy always operates in VC mode (Voltage Control, Figure 9). The desired output
voltage must be set by using the "Setpoint voltage" parameter. The generator will now maintain
the set output voltage and adjust it with more or less current if needed - depending on the load.
The charging current depends on the generator and possible dirt on the charging bar/electrode.
The maximum output current can be set by using the "Output current limit" parameter. The
output current will only drop when the "Output current Limit" parameter value is reached.

6.5.3 Continuous and Remote mode

The default setting for the CMM IQ Easy is Continuous mode (Figure 11). If the generator is in
Continuous mode, the high voltage at the output becomes active when the following conditions
are met:
-
the generator must be in "Run" mode
-
a setpoint must be set.
If the CMM IQ Easy is in Remote mode, the following conditions must be met to activate the
high voltage at the generator's output:
-
the generator must be in "Run" mode
-
a setpoint must be set
-
on the Manager IQ Easy's machine connector, a "Remote On" signal must be indicated.
For more information about the "Remote On/Off" signal, please read the Manager IQ Easy
manual.

6.5.4 Charge pulse single shot (in Remote-mode only)

The "Charge pulse single shot" parameter (Figure 11) ensures that the high voltage at the
generator's output is active for a fixed period of time (which can be set) once the "Remote On"
signal has been received. The default setting for the "Charge pulse single shot" is 0 ms
(=inactive).
CMMEasyCMMIQEasy_UM_9752098500_NL_D_GB_F_V3_1
, the generator is now shown as in Figure 8.
Figure 12.
to put the
GB
57