7.2.1 Information/settings tab

You can scroll through the different pages by using the
information can be found here:
-
Output voltage (kV): indicates the present high voltage value at the HV output
-
Output current (mA): indicates the present current value at the HV output
-
Output voltage peak (kV): indicates the high voltage peak value at the HV output. These
are updated after e
-
Output current peak (mA): indicates the peak value of the current at the HV output. These
-
Last warning: date and time when the last warning occurred
-
Last alarm: date and time when the last alarm occurred

7.2.2 Graphics tab

In the Graphics tab (Figure 14), operation is graphically displayed as a function of time:
-
Blue: the output voltage at the HV output (kV).
-
Yellow: the output current at the HV output (mA).
If you click anywhere on the screen, the screen freezes and "On hold" will be displayed. By
clicking again, the present value will be indicated again.

7.2.3 ActionLog tab

In the ActionLog tab (Figure 15) tab wordt stap voor stap een veranderde status van de CMM
IQ Easy gelogd. This is indicated with the date and time when the status change occurred. The
most important notifications are:
-
CYCLE OK: the generator is switched on and operates OK
-
CYCLE NOT OK: the generator is switched off or the high voltage is not OK
-
REMOTE ON:
-
REMOTE OFF:
The ActionLog tab can be cleared in the Maintenance tab (Figure 17).

7.2.4 DataLog tab

Any available measurement data of the CMM IQ Easy is logged at fixed times in the DataLog
tab (Figure 16). The most important measurement values are:
-
Umax (kV): peak voltage at the high voltage output
-
Imax (mA): peak current at the high voltage output
The DataLog tab can be cleared in the Maintenance tab (Figure 17).
These log values are also saved in the Manager IQ Easy's log file when the "Data logging"
parameter in the manager and the "Data logging" parameter in the CMM IQ Easy (Figure 12)
are switched on. The log interval is determined by the "Logfile refresh time" parameter in the
Manager IQ Easy. For information about the log file, please see the operating instructions of the
manager.