Table 3, Troubleshooting CMM IQ Easy (wiring diagram IQ 5.3.2)
Problem
All LEDs are off
LEDs do not light
up orange, but
keep flashing green
LEDs light up red
LEDs flashing red
slowly, 1Hz
LEDs flashing red
quickly, 5Hz
CMMEasyCMMIQEasy_UM_9752098500_NL_D_GB_F_V3_1
Possible cause
No supply voltage
Faulty wiring
Cable rupture in the M12
connection cable/connector
High voltage set too low
CMM IQ Easy is not in "Run"
mode
"Remote On/Off" signal inactive
Output voltage set too high,
arcing at charging bar/electrode
Short circuit between charging
bar/electrode or HV cable and
earth
Generator overheated
CMM IQ Easy supply voltage too
low
Warning/Alarm output current too
low/high
Charge pulse too long
Eeprom reading error warning
Eeprom reading error alarm
No communication between the
CMM IQ Easy and the Simco-Ion
IQ platform
Solution
Switch on 24 V DC supply
voltage (switch on Manager IQ
Easy)
Locate fault and remedy, see 5.3
Replace M12 cable/connector
Increase output voltage by
increasing setpoint (5.3/6.2/6.5)
Put the CMM IQ Easy in "Run"
mode (6.5)
Activate the "Remote On/Off"
signal or put the CMM IQ Easy in
"Continuous" mode (6.5)
Reduce output voltage by
reducing setpoint or increasing
distance to earth
Locate short circuit and eliminate
Check if the ambient temp. is
below 55ºC
Check the supply voltage
Set the "Setpoint Warning/Alarm
min./max. output current peak"
correctly (6.5)
Set the charge pulse time and
the charge pulse warning
correctly (6.5)
Check the parameter settings
and restart the CMM IQ Easy
The CMM IQ Easy is faulty,
request an RMA number
(Chapter 10)
Check the wiring between the
CMM IQ Easy and the Simco-Ion
IQ platform
Restart the Simco-Ion IQ
platform.