Figure 7, CMM IQ Easy in Standby mode
In the Manager IQ Easy's main screen, click the CMM IQ Easy symbol to check the inbound
generator parameters. Press
and then
behind the desired parameter in order to change it.
If an "Undefined param" appears on the info screens of the CMM IQ Easy on the
Manager, the manager must be updated with the latest software.
Download the latest software version on
and follow the "Upgrade" instructions as described in the Manager manual.
The "Device name" and "Machine position/name" parameters can be changed at your own
discretion. This could be useful to keep track if multiple CMM IQ Easys are connected to one
machine.
Figure 9, Changing CMM IQ Easy parameters
To activate the high voltage output of the CMM IQ Easy, the following conditions must be met:
The generator must be in "Run" mode (6.5.1 Standby, Run and Autorun)
A "Setpoint" must be set (6.5.2 Control mode)
The "Remote" signal must be active or the generator must be in Continuous mode (6.5.3
Continuous and Remote mode)
The present output voltage and current can be read with the "Output voltage" and "Output
current" parameters (Figure 10).
The maximum peak output voltage and output current can be read with the "Output voltage
peak" and "Output current peak" parameters (Figure 10). These peak values are updated after
CMMEasyCMMIQEasy_UM_9752098500_NL_D_GB_F_V3_1
Figure 8, CMM IQ Easy in Run mode
to go to the previous/next tab (Figures 9 and 10). First click
www.simco-ion.co.uk/software
Figure 10