6.5.5 Charge pulse min/max time (in Remote-mode only)

The "Charge pulse min time" parameter (Figure 11) ensures that the high voltage at the
generator's output is active for a minimum period of time (which can be set) once the "Remote
On" signal has been received. If the "Remote On" signal is longer than the set time for "Charge
pulse min time", the "Remote On" signal takes precedence. The high voltage will then follow the
"Remote On" signal. The default setting for the "Charge pulse min time" is 0.00 sec (=inactive).
The "Charge pulse max time" parameter is a "Warning" setting. If the high voltage at the
generator's output is active longer than the "Charge pulse max time" value set, a warning will
appear on the Manager IQ Easy's screen. The default setting for the "Charge pulse max time" is
0.00 sec (=inactive).

6.5.6 Cycle OK parameters

Cycle OK high delay (Figure 12), between the moment the CMM IQ Easy detects that the
cable(s) have been charged and activation of the "Cycle OK"-signal, an additional delay can be
set in order to increase process stability.
Cycle OK low level, the level where the CMM IQ Easy detects that the charge of the electrode
has decreased sufficiently can be adjusted for additional process optimisation.

6.5.7 Setpoint Warning/Alarm min./max. output current peak

With the "Setp warning min outp cur pk", "Setp warning max outp cur pk", "Setp alarm min outp
cur pk" and "Setp alarm max outp cur pk" parameters (Figure 13), warnings and alarms can be
set to monitor the minimum and maximum output current peaks. The default setting for these
parameters is 0,00 mA (=inactive)