DC HIGH-VOLTAGE GENERATOR USER MANUAL

1. Introduction

This manual applies to the Simco-Ion CM Medium high-voltage generator.
Read through the whole manual before you install and put the generator into use.
Follow the instructions set out in this manual to ensure proper operation of the product and to
retain your entitlement under the guarantee.
Where the word generator is used in this manual, it refers in all cases to the CM Medium high-
voltage generator.
The terms of the guarantee are set out in the General Conditions for the Sale and Delivery of
Products and/or Performance of Activities by SIMCO (Nederland) B.V.

2. Safety

 The CM Medium high-voltage generator is intended to generate high voltages for charging
bars and electrodes.
 Work on the equipment must be carried out by a skilled and qualified electrical engineer.
 When carrying out work on the equipment: de-energise the equipment.
 Do not touch any live points, you will get an unpleasant electrical shock.
 Make sure that the equipment is properly earthed, this is necessary for correct and safe
operation.
If changes, adjustments, etc. have been made without prior consent in writing, or if original
parts have not been used for repairs, CE approval for the equipment will be withdrawn and
the equipment will no longer be under guarantee.
 High voltages are hazardous for people who have a pacemaker.

3. Use and operation

The CM Medium high-voltage generator feeds Simco-Ion charging bars/electrodes. This
combination is called the Simco-Ion "Chargemaster" electrostatic charging system.
It allows you to temporarily bond certain materials.
The CM Medium high-voltage generator is a switched-mode power supply.
The generator output current is electronically restricted. The output voltage can be set between
0 kV and maximum.
The generator incorporates functions for remote switching on and off, and for remote setting of
the output voltage (not wireless).