9 Unit settings menu

9.3 Ventilation

Volumetric flow measurement (nominal ventila-
tion)
Volumetric flow Ventilation level Reduced ventila-
tion
Volumetric flow Ventilation level Nominal ventila-
tion
Volumetric flow Ventilation level Intensive ventila-
tion
EA/SA (exhaust air/supply air) adjustment Re-
duced ventilation
EA/SA adjustment Nominal ventilation
EA/SA adjustment Intensive ventilation

Night-time cooling/flush mode

Air volume Volumetric flow compensation (opera-
tion with exhaust air system)
Unit filter
Filter service life of unit filter
Filter change of unit filter
External filter
Filter service life of external filter
Filter change of external filter
Room filter
Filter service life of room filter
Filter change of room filter

Duration of ventilation level

Motion detector overrun time

Supply and exhaust air valves are set during ini-
tial commissioning. Open or close them to set the
values specified by the planning office.
9.3.1 Volumetric flow measurement (nominal
ventilation)
Volumetric flow measurement (nominal ventila-
tion)
Parameters: Volumetric flow measurement (nom-
inal ventilation)
Set value: On / Off
After activating the volumetric flow measurement,
the fans are run for a maximum of 3 hours in
nominal ventilation. This allows the supply and
exhaust air volumetric flows in the building to be
calibrated without the air volumes being changed
by sensor values. The function switches off auto-
matically after 3 hours. The function can be
switched off manually.
40

9.3.2 Volumetric flow of ventilation level

Reduced ventilation RV (in m³/h)
Type
Min.
WS 310 / WS
80
320 ..
WS 410 / WS
80
470 ..
WS 170
40
WS 160 Flat
40
WS 300 Flat
80
Trio
40
Nominal ventilation NV (in m³/h)
Type
Min.
WS 310 / WS
80
320 ..
WS 410 / WS
80
470 ..
WS 170
40
WS 160 Flat
40
WS 300 Flat
80
Trio
40
Intensive ventilation IV (in m³/h)
Type
Min.
WS 310 / WS
80
320 ..
WS 410 / WS
80
470 ..
WS 170
40
WS 160 Flat
40
WS 300 Flat
80
Trio
40
The volumetric flow setting applies to both fans.
With humidity protection ventilation, the fans run
in intermittent operation. We recommend setting
the volumetric flow for NV first.
The RV and IV volumetric flows are set automat-
ically by the control on the basis of the NV refer-
ence value 1/3 less than (RV) and 1/3 greater
than (IV).
Example WS 310/410, WS 320/470, WS 300
Flat:
NV 150 → RV 100 → IV 200
Factory
Max.
set
120
320
160
490
60
160
60
160
100
300
60
120
Factory
Max.
set
180
320
240
490
90
160
90
160
150
300
90
120
Factory
Max.
set
240
320
320
490
120
160
120
160
200
300
120
120