System Settings Menu; Operating Structure For System Settings; Display; Time Programme - Maico RLS T2 WS Notice De Montage Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8 System settings menu

Mode of operation: Interval operation, approx. 43
% of reduced ventilation (according to DIN
1946-6).
Ventilation level: ventilation level 1
Mode of operation: Continuous operation with re-
duced ventilation RV
Ventilation level: ventilation level 2
Mode of operation: Nominal ventilation NV
Ventilation level: intermittent ventilation
Mode of operation: Time-limited intensive ventila-
tion IV (with timer).
Ventilation level: ventilation level 3
Mode of operation: Intensive ventilation IV
36
8 System settings menu
Basic control unit settings, such for example key
lock or luminosity, can be configured in the Sys-
tem settings menu. You can also switch to the in-
staller level. Within this level, the system configur-
ation for the multiple-unit connection (max. 5 unit)
to the RLS T2 WS should be set.
8.1 Operating structure for system
settings

Display

Time programme

System (unit settings)
Installer

Software version

Error memory (fault messages)
Notes
8.2 Display
Parameters: language
Set value: currently: German, English, French
Parameters: date/time
Set value: hours/minutes/day/month/year
Parameters: key lock (configuration only possible
in installer level)
Set value: yes/no
Parameters: Change key lock code (between 4
and 8 digits are possible)
Set value: Factory settings: 0000

Publicité

Table des Matières
loading

Table des Matières