POSSIBLE CHARGING PROGRAMMES

6 Volt mode
Charging programme for 6 V batteries, 1.2 Ah to 14 Ah, temperatures above 0°C
Charge current:
charge voltage:
6 Volt winter mode
Charging programme for 6 V batteries, 1.2 Ah to 14 Ah, temperature below 0°C
Charge current:
charge voltage:
Motorbike mode
Charging programme for 12 V batteries from 1.2 Ah to 14 Ah, temperatures above 0°C
Charge current:
charge voltage:
Motorbike winter mode
Charging programme for 12 V batteries from 1.2 Ah to 14 Ah, temperatures below 0°C
Charge current:
charge voltage:
Car mode
Charging programme for 12 V batteries from 14 Ah to 150 Ah, temperatures above 0°C
Charge current:
charge voltage:
Car winter mode
Charging programme for 12 V batteries from 14 Ah to 150 Ah, temperatures below 0°C
Charge current:
charge voltage:
Battery maintenance charge mode (only when not installed)
As soon as the battery is fully charged, the charger switches automatically over
to battery maintenance charge mode. This is indicated appropriately on the display.
Do not leave the battery charger connected for more than 5 days.

ERROR MESSAGES

Display of error after faulty connection (wrong poles), short-circuit (battery short-circuit),
no contact, selection of an incorrect charging programme or overheating.
Error message in 6 V – mode, if a battery is connected with less than 5.5 V ± 0.2 or the voltage
is still lower than 6 V after 4 hours of charging time.
In this case, the battery is defective and must be replaced.
12
2.5 A maximum
7.2 V
2.5 A maximum
7.4 V
2.5 A maximum
14.6 V
2.5 A maximum
14.8 V
5 A maximum
14.6 V
5 A maximum
14.8 V