6.3 PROTECTION FROM CONNECTION TO THE WRONG POLE

The device is equipped with a fuse in order to protect the user from injury and the device from damage in case of accidental connec-
tion to the wrong poles. In the event of a wrong connection, this fuse is activated and subsequently requires a replacement with a fuse
of the same type. This fuse is located in a bracket at the bottom of the device.

6.4 CHARGING OF BATTERY

Now, connect the power plug of the charger to the mains socket. The charging process has now started and the control LED „LADEN"
(CHARGING) lights up. The charging time of the battery depends on several factors, such as the capacity of the battery, the ambient
temperature, the battery level, the performance of the charger, etc. An empty 36 Ah battery, at an ambient temperature of 20 °C,
is fully loaded with this device in approx. 9 hours. It is very important to monitor the charging process in short intervals in order to
prevent overcharge damages. Finish the charging process when the control LED „VOLL" (FULL) is lit up by pulling the mains cable of
the battery charger from the mains socket.

6.5 REMOVING OF CHARGER

Attention: First, pull the mains power plug from the socket and observe the sequence when disconnecting. This prevent
the generation of sparks. This is extremely important for your safety, as highly explosive oxyhydrogen is generated during
the charging process. Separate the charger from the supply network.
Then, remove the connection of the black clamp (-). Now, remove the battery clamp from the positive pole (+) of the
battery. Allow the battery to cool down and fill the cells with distilled water up to the level specified by the battery ma-
nufacturer. Close the battery cells with the stoppers.

7. MAINTENANCE AND CARE

Maintenance: The device is maintenance-free if used according to its intended purpose.
Care: Clean the pole clamps after each charging process. Remove all battery acid splashes from the pole clamps to prevent corrosion.
Carefully clean the device with a dry cloth. Do not use liquids or chemical cleaning agents. Never submerge the device in liquid. Never
allow liquid to run over the device. Insert the cable holders in the top bores of the casing screws on the back of the device. Properly
roll up the cable before storing the device to prevent damage to the cables and the device. Store the device in a dry and clean location.

8. INFORMATION REGARDING ENVIRONMENTAL PROTECTION

Do not dispose of the device in household garbage. Electrical and electronic scrap has to be collected separately and dis-
posed of in an environmentally responsible manner for recycling. Please contact your community or city administration
regarding disposal options for electronic scrap.

9. CONTACT INFORMATION

EAL GmbH
Otto-Hausmann-Ring 107
42115 Wuppertal, Germany
+49 (0)202 42 92 83 0
+49 (0) 202 42 92 83 – 160
info@eal-vertrieb.com
www.eal-vertrieb.com
7

Publicité

Chapitres

Table des Matières
loading

Table des Matières