6. OPERATING INSTRUCTIONS

6.1 OVERVIEW

1 Power cable
2 Pole callipers, black (-)
3 Charging control lamp
4 Control button for battery display
5 Charge status display
6 12 V output sockets
7 Pole callipers, red (+)

6.2 CHARGING THE POWER PACK

Charge the power pack for 24 hours before you use it for the first time. To do this, place the power pack in a well-ventilated
location. Plug the power cable (1) into a 230 V socket. The charging control lamp (3) now lights up red. After 24 hours, pull the
plug and coil the cable on to the designated holders. Press the control button for the battery display (4), the charge status display
(5) „high" lights in green. The power pack is now ready for use.
In order to ensure that the power pack is always able to provide its full power performance, charge for at least 5 hours after each
use (to start a vehicle).

6.3 CHECKING THE CHARGE STATUS

In order to check the charge status of the power pack, press the control button for the battery display (4) when the power cable
is disconnected. The control lamps of the charge status display (5) show the status of the battery:
Low (red):
Medium (green):
High (green):

6.4 STARTING PROCEDURE

Make sure that the power pack is fully charged. To do this, press the control button for the battery display (4). If the control lamp
(5) lights „high" green, the power pack is ready for use.
The starting aid function of the power pack is designed only for vehicles with a 12 V on-board voltage.
Before using, consult the operating instructions of your vehicle to determine whether, and if so, how
an external starting aid is to be used. Modern vehicles have sensitive electronics and control devices
that may be damaged if the wrong procedure is used.

6.5 CONNECTING THE POWERPACK (VEHICLES WITH NEGATIVE EARTH)

Switch off the ignition and all electrical consumers of the vehicle (radio, lights, rear window heating, seat heating etc.). Apply
the parking brake.
First connect the red (+) pole callipers (7) to the plus pole of your vehicle battery. The black (-) pole callipers (1) is connected, as
far as possible from the battery, to the motor block or chassis (not to a painted part).

6.6 ATTEMPTING TO START

Start the motor. Do not operate the starter for longer than 6 seconds. The battery of the power pack is not designed for longer
starting attempts. Pause for at least 5 minutes between two starting attempts. If the motor does not start after a number of
attempts, abort the process and investigate the cause of the defect.

6.7 REMOVING THE POWER PACK

First disconnect the black (-) pole calliper, coil the cable and attach the pole calliper to the designated holder. Then disconnect
the red (+) pole calliper, coil the cable and attach the pole calliper to the designated holder. Always maintain this sequence.
Recharge the power pack.
8
The battery must be charged as soon as possible
Charging the battery is recommended
It is not necessary to charge the battery