OPEraTiON
Settings and displays
4.3
Setting the temperature
2
1
1 Set temperature selector (no end-stop): OFF, 20 - 60 °C
2 To call up/assign preferred temperatures
Settings
Setting
Step
20 °C ... 60 °C
0.5 °C
4.4
Internal anti-scalding protection (qualified
contractors)
If required, the qualified contractor can set a permanent temper-
ature limit, for example in nurseries, hospitals, etc.
When supplying a shower, the appliance temperature setting
range must be adjusted by the qualified contractor to 55 °C or less.
If the anti-scalding protection function is enabled and the tem-
perature limit is reached, "Tmax" flashes.
4.5
Setting the Tmax temperature limit
(childproofing)
You can adjust the temperature limit individually. If the tempera-
ture limit is enabled, "Tmax" is shown on the display.
4.5.1 Enabling the temperature limit
See chapter "Settings in the parameter menu".
4.5.2 Disabling the temperature limit
f Proceed as per menu item "Enabling the temperature limit".
f
f Turn the temperature selector to "OFF".
f
6
| DCE-X Premium
Setting
Step
68 °F ... 140 °F
1 °F
4.6
Assigning values to the temperature memory
buttons
Memory buttons "1" and "2" can each be assigned a preferred
temperature.
f Select the preferred temperature.
f
f To save the preferred temperature, press and hold button
f
"1" or "2" for more than 3 seconds. The selected temperature
flashes once to confirm.
4.7
Inlet temperature information
If the appliance is operated with preheated water and the inlet
temperature exceeds the selected set temperature, the inlet tem-
perature is indicated on the second display line and flashes. The
water is not heated further.
4.8
Info menu
The appliance has an additional display where consumption values
can be shown.
4.8.1 Calling up the info menu
f Briefly press "i" until "i 1" appears, then continue to press "i"
f
to see further menus.
f Exit the menu item by pressing "i" and holding for more than
f
5 seconds. Alternatively: The system exits the menu item au-
tomatically 30 seconds after the setting has been completed.
menu Description
Explanation
I 1
Flow rate
The current flow rate
is shown.
I 2
Time
The current time is
shown.
I 3
Energy consump-
The amount of en-
tion
ergy consumed is
shown.
I 4
Water consump-
The amount of water
tion
consumed is shown.
Note
The consumption values are calculated starting from the
last reset.
Screen | display
Flow rate in l/min or
gpm
Time
Value in kWh
Value in m³ | gal
www.stiebel-eltron.com