iNSTallaTiON

maintenance

16. Maintenance
WARNING Electrocution
Before performing any work on the appliance, discon-
nect all poles from the power supply.
Draining the appliance
The appliance can be drained for maintenance work.
WARNING Burns
Hot water may escape when you drain the appliance.
f Close the shut-off valve in the cold water inlet line.
f
f Open all draw-off valves.
f
f Undo the water connections on the appliance.
f
f Store the dismantled appliance free from the risk of frost, as
f
water residues remaining inside the appliance can freeze and
cause damage.
Cleaning the strainer
If the strainer in the threaded cold water fitting is dirty, clean it.
Close the shut-off valve in the cold water inlet line before remov-
ing, cleaning and refitting the strainer.

17. Specification

17.1 Dimensions and connections

217
140
175
b02
100
c06
b02 Entry for electrical cables I
c01
Cold water inlet
c06
DHW outlet
18
| DCE-X Premium
97
32
35
c01
109
Premium
Finished walls
Male thread
Male thread
Alternative connection options
b03
b02 Entry for electrical cables I
b03 Entry for electrical cables II
c01
Cold water inlet
c06
DHW outlet

17.2 Wiring diagram

DCE-X Premium
L
L
L
N
2
1
1 Power PCB with integral safety switch
2 Bare wire heating system
3 High limit safety cut-out
4 Mains terminal
DCE-X
G 1/2 A
G 1/2 A
b02
30
b03
b02
b02
15
b02
100
c06
c01
Finished walls
Unfinished walls
Male thread
Male thread
2/GRD ~ 220 - 240 V
1/N/PE ~ 220 - 240 V
4
L
L
L
N
www.stiebel-eltron.com