Settings; Setting The Temperature Limit; Shutdown; Troubleshooting - Stiebel Eltron SHC 10 Utilisation Et Installation

Masquer les pouces Voir aussi pour SHC 10:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
INSTALLATION

Settings

11. Settings

11.1 Setting the temperature limit

1 Limiting ring
Temperature settings:
2 38 °C
3 49 °C
4 65 °C
Placing the limiting ring behind the temperature selector allows
you to limit the setting range of the temperature selector to a
specific maximum temperature.
f Turn the temperature selector to zero (fully to "*").
f
f Pull off the temperature selector and the limiting ring.
f
f Push the limiting ring with the required maximum setting
f
onto the appliance cover.
f Install the temperature selector set to zero ("*").
f

12. Shutdown

f Isolate the appliance from the power supply by removing the
f
plug or by tripping the MCB in the fuse box.
f Drain the appliance (see chapter "Installation / Maintenance /
f

Draining the appliance").

13. Troubleshooting

Fault
Cause
The appliance does
The high limit safety
not supply hot water.
cut-out has tripped.
The controller is faulty. Replace the combined tem-
The flanged immersion
heater is faulty.
Loud boiling noises
The appliance is scaled
inside the appliance.
up.
Water drips from the
The safety valve is
safety valve after
scaled up or dirty.
heat-up.
8
| SHC 10 | SHC 15
1
2
3
4
Remedy
Remedy the cause of the fault.
If necessary, replace the com-
bined temperature controller /
high limit safety cut-out. Make
the high limit safety cut-out
operational by pressing the
reset button on the high limit
safety cut-out (see chapter
"Installation / Troubleshooting /
Activating the high limit safety
cut-out").
perature controller / high limit
safety cut-out.
Replace the flanged immersion
heater.
Descale the appliance.
Clean / descale the valve seat.

13.1 Activate high limit safety cut-out

f Open the appliance (see chapter "Installation / Maintenance /
f
Opening the appliance").
f Pull off the adaptor.
f
f Press the reset button on the high limit safety cut-out.
f
f Fit the adaptor.
f
f Close the appliance cover.
f
f Fit the limiting ring and temperature selector.
f
1
1 Adaptor
2 Reset button, high limit safety cut-out

14. Maintenance

WARNING ELECTROCUTION
Before any work on the appliance, disconnect all poles of
the appliance from the power supply.
f Dismantle the appliance for maintenance work.
f

14.1 Checking the safety valve

f Check the function of the safety valve regularly.
f
14.2 Draining the appliance
WARNING Burns
Hot water may escape during the draining process.
f Drain the appliance via its connectors.
f
2