Mesto FERROX 3565 Mode D'emploi page 16

Masquer les pouces Voir aussi pour FERROX 3565:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
GB
IRL
The pump handle is locked in place. (Fig. 5).
3. Unscrew the pump [2] from the tank [1]. (Fig. 6).
+
To ensure the pump remains clean during storage, we recommend you attach the
pump [2] to the pump holder [8]. (Fig. 7).
+
We recommend you mix the spraying liquid in the device or premix it in an external
tank: Fill to 1/3 with water, pour in the spraying agent, and then add more water until full.
4. Add the spraying liquid to the tank [1] (Fig. 7).
5. Check the filling height through the viewing glass [15] of the shut-off valve [9]. (Fig. 8).
All excess pressure must be released from the device.
+
Move the shut-off valve [9] on the tank [1] from top to bottom several times while
pressing the lever (the level of liquid in the hose line and tank is equalized). The
level of liquid visible in the viewing glass [15] then corresponds to the filling height
of the tank, which can be read on the scale [14]. (Fig. 8).
6. Screw the pump [2] into the tank [1]. (Fig. 9).
7. Swivel in the pump holder [8]. (Fig. 9).
Without compressed-air filling valve
8. Press the pump handle [13] down and turn it clockwise.
► The pump handle is unlocked. (Fig. 10).
9. Generate the required pressure (→ Table 2) in the tank [1] (Fig. 11).
+
The maximum pressure should not exceed 6 bar (red line on the pressure gauge
[16], Fig. 11). If the maximum pressure is exceeded, the safety valve will engage
and release the excess pressure.
10. Press the pump handle [13] down and turn it counterclockwise.
► The pump handle is locked in place. (Fig. 5).
With compressed-air filling valve (option)
8. Connect the compressed-air hose [17] to the compressed-air filling valve [18]. (Fig. 12).
Pressure is built up (max. 6 bar).
Ensure that the initial pressure is not higher than 15 bar.
9. When the required pressure has built up (→ Table 2), remove the compressed-air hose [17].
Spraying
Observe the instructions in the section entitled „Safety".
Operate the device only while it is vertical or suspended upright and nearly
vertical.
Avoid allowing drops of spray to drift onto areas that are not being treated.
Observe the instructions of the spray product manufacturer!
1. Suspend the device from your shoulder or place it on your back. (Fig. 13 and/or 14)
+
To prevent dripping, hold the spray lance up when first spraying and activate the
shut-off valve until no more liquid mixed with air is emerging.
2. Activate the shut-off valve [9] (Fig. 15).
Spraying may now begin.