8
Interrupting Pb
Refresh
Resuming Pb Re-
fresh
CAUTION! Risk of sparks if the charging leads are disconnected too soon. Before
disconnecting the charging leads, press the Stop/Start key to end the charging
process.
To end refresh charging:
7
-
Disconnecting the charger
-
Disconnect the black charging lead from the negative pole (-) of the battery
-
Disconnect the red charging lead from the positive pole (+) of the battery
NOTE! Risk of damage to connection sockets and connecting plugs. Do not dis-
connect or unplug charging leads while reactivating.
Press the Stop/Start key while reactivating
1
-
Press the Stop/Start key
2
-
-
A set of four bars shows the state of
charge of the battery (e.g. three bars
represent a state of charge of 80%).
-
All four bars are continuously display-
ed.
-
The state of charge is 100%.
-
The battery is ready to use.
-
The battery may remain connected to
the charger for any length of time.
-
Conservation charging counteracts
battery self-discharge.
If Refresh mode is not carried out success-
fully, error message 35 or 36 appears. In
this case check the settings, adjust them if
necessary and then repeat the procedure.
Press the Stop/Start key
Pb Refresh is interrupted
Pb Refresh is resumed
69