10. t
roublEshooting
Error
The motor does not start
after switching it on, there
is no signal sound
The motor does not start
after switching it on, there
is an alarm
(double alarm, repeated at
1 second intervals).
The motor does not start
after switching it on, there
is an alarm
(single alarm, repeated
about every 2 seconds).
The motor is running in the
reverse direction.
Cause
The connection between
battery and speed controller
is loose.
The connection between
motor and speed controller
is loose.
Input voltage too high or
too low.
Input signal is faulty.
The connection cables
between motor and speed
controller have been swit-
ched.
The chassis provides for ano-
ther installation direction of
the motor.
- -
Solution
Check the plug connection.
Replace the contacts.
Check the plug connection.
Replace the contacts.
Check the charge of the bat-
tery pack.
Check sender and receiver.
Check the connection of
channel 2 of the receiver
(accelerator/brake signal) to
the speed controller.
Switch any two connection
cables of motor to speed
controller.
Program the other rotation
direction in programming
step 11.