INSTALLATION
For FTBX Models:
a. Connect the on-site power supply through the power
input knockout to the POWER IN terminal block.
b. Connect power from the POWER OUT terminal block,
through the power output knockout, to the solenoid
valve on the frost top enclosure.
c. Connect the temperature probe wire from the frost top,
through the probe wire inlet, to the digital temperature
controller.
Temperature probe installed here.
Wire from probe connects to control panel
(same for FTBR Models).
FTBX Model Electrical Connections

Installing the Control Panel

Use the following procedure to install the control panel remotely.
WARNING
Control panel must be mounted in a vertical surface.
Mounting control panel in a horizontal surface may result
in the collection of liquids and lead to electric shock.

Countertop Cutout Dimensions

Width
Model
(A)
FTBR-3/4
16-1/2" to 17-1/16"
and
(419 to 433 mm)
FTBX-3/4
FTBR-1
27-7/16" to 28"
and
(697 to 711 mm)
FTBX-1
FTBR-2
37-3/8" to 38"
and
(949 to 965 mm)
FTBX-2
Solenoid Valve
Power Input
Depth
(B)
19-7/16" to 20-1/8"
(494 to 511 mm)
19-7/16" to 20-1/8"
(494 to 511 mm)
27-5/16" to 28"
(694 to 711 mm)
FTBR, FTBX, FTBR-S, and FTBX-S Series Countertop Cutout Dimensions.
1. Cut and drill the appropriate holes in the mounting surface.
Refer to the "Control Panel Cutout and Screw Hole
Dimensions" chart for the cutout dimensions.
2. Remove the four trim cover screws from the control panel
and remove the trim cover.
3. Position the control panel into the cutout opening through
the backside.
4. Fasten the control panel to the vertical surface using four
screws (not supplied).
5. Apply a 1/4" (6 mm) bead of NSF-approved silicone sealant
where the trim cover will contact the cabinet surface. Refer
to the "Control Panel Cutout and Screw Hole Dimensions"
illustration for more information.
6. Reinstall the trim cover on the control panel and secure
in position using the four trim cover screws. Make sure to
embed the trim cover edge into the silicone.
7/16"
(11 mm)
3/8"
(9 mm)
Control Panel Cutout and Screw Hole Dimensions
NOTE: Make sure the width of the control panel cutout does
not exceed the above dimension.
Model
FTBR-3
55-3/8" to 56"
and
(1406 to 1422 mm)
FTBX-3
FTBR-S2
53-5/16" to 54"
and
(1354 to 1372 mm)
FTBX-S2
FTBR-S3
79-3/16" to 79-7/8"
and
(2011 to 2029 mm)
FTBX-S3
B
A
10
English
Silicone Sealant
1-1/16"
(27 mm)
5-5/8"
(143 mm)
3-1/2"
(89 mm)
7-7/16"
(189 mm)
7-3/4"
(196 mm)
Width
Depth
(A)
(B)
27-5/16" to 28"
(694 to 711 mm)
19-7/16" to 20-1/8"
(494 to 511 mm)
19-7/16" to 20-1/8"
(494 to 511 mm)