Logic
Definition
Serial mode
(Identifies
how board is
SERIAL MODE
configured in
a BFT network
connection).
Address
ADDRESS
lg1
Logica 1
Logic 72*
lg2
Logica 2
Logic 73*
Configuration
of EXPI1 input
on input-output
EXPI1
expansion
board.
1-2
Configuration
of EXPI2 input
on input-output
EXPI2
expansion
board.
1-3
Configura-
tion of EXPO1
output
EXPO1
on input-output
expansion
board
4-5
INSTALLATION MANUAL
Cross
out
Default
setting
used
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
0
1
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other boards.
Identifies board address from 0 to
0
[ ___ ]
(see U-LINK OPTIONAL MODULES section)
0
Function disabled.
VEGA : The operation ordered next will be used as a SET operation (complete opening-closing operation uninterrupted
by intermediate stops, to acquire the torque necessary for movement).
WARNING! Obstacle detection is not active.
VEGA ULTRA: At the first START after power supply, the door will search for the closing end stop and will automa-
0
1
tically perform an opening and closing cycle to obtain the required torque for the movement.
WARNING! : Obstacle detection is not active.
It is recommended to position the door already closed and check that there are no obstacles during movement.
The manoeuvre may be interrupted and the procedure may be repeated by switching off the power supply before
completing the closing operation
At the end of the closing manoeuvre, the LG1 logic is set to 0
Terminals 28-29 output as solenoid lock.
0
0
1
Terminals 28-29 output as flashing light (bulb connected max. 24V 3W).
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing the mo-
11*
vement stops.
1
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the mo-
12*
vement stops.
Input configured as Phot test safety, tested photocell. Input 3 (EXPI2) on input/output expansion board is switched
13*
automatically to safety device test input, EXPFAULT1.
Input configured as Phot op test safety, tested photocell active only while opening. Input 3 (EXPI2) on input/output
14*
expansion board is switched automatically to safety device test input, EXPFAULT1
Input configured as Phot cl test safety, tested photocell active only while closing. Input 3 (EXPI2) on input/output
15*
expansion board is switched automatically to safety device test input, EXPFAULT1
Input configured as Bar safety, tested safety edge. Input 3 (EXPI2) on input/output expansion board is switched
16*
automatically to safety device test input, EXPFAULT1.
Input configured as safety Bar OP test, safety edge with inversion active only while opening, if while closing the
17*
movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
Input configured as safety Bar CL test, safety edge with inversion active only while closing, if while opening the
18*
movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
0
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing the mo-
11*
vement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the mo-
12*
vement stops.
0
Output configured as monostable Radio Channel.
1
Output configured as SCA (gate open light).
11
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light.
Optional extras
119
in a local BFT network connection.
- 41
VEGA - VEGA ULTRA