TABLE "B" - LOGIC MENU - (logic)
Logic
Definition
Motor type
MOTOR TYPE
(Set the type of
(only for VEGA
motor connected
CPEL)
to the board).
Automatic
TCA
Closing Time
Fast closing
FAST CLS.
STEP-BY-STEP
Step-by-step
movement
MOVEMNT
Pre-alarm
PRE-ALARM
Block pulses
IBL OPEN
during opening
Block pulses
|IBL TCA
during TCA
Block pulses
IBL CLOSE
during closing
Hammer during
RAM BLOW C. O P
opening
Closing limit
PRESS SWC
switch pressure
Ice feature
ICE
1 motor active
1 MOT. O N
OPEN IN
Open in other
OTHER DIRECT
direction
(only for VEGA)
Configuration
of safety input
SAFE 1
SAFE 1.
72
INSTALLATION MANUAL
Cross
out
Default
setting
used
0
PHEBE BT A U
0
1
PHEBE ULTRA BT A
0
Logic not enabled
0
1
Switches automatic closing on
0
Logic not enabled
0
1
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Inputs configured as Start E, Start I, Ped
0
operate with 4-step logic.
Inputs configured as Start E, Start I, Ped op-
1
erate with 3-step logic. Pulse during closing
0
reverses movement.
Inputs configured as Start E, Start I, Ped op-
2
erate with 2-step logic. Movement reverses
with each pulse.
0
The flashing light comes on at the same time as the motor(s) start.
0
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
0
Logic not enabled
Before opening completely, the gate pushes for approx. 2 seconds as it closes. This allows the solenoid lock to
0
1
be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Movement is stopped only when the closing limit switch trips: in this case, the tripping of the closing limit
0
switch must be adjusted accurately.
1
This function allows leaves to press against the mechanical stop without this being considered as an obstacle.
1
After intercepting the closing limit switch, the motor continues to be supplied for 3s longer.
0
The Amperostop safety trip threshold stays at the same set value.
The controller automatically adjusts the obstacle alarm trip threshold at each start up.
Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the
0
1
value laid down by standard EN 12453. If in doubt, use auxiliary safety devices.
This feature is useful when dealing with installations running at low temperatures.
WARNING: once this feature has been activated, you will need to perform an autoset opening and closing cycle.
Checks the second motor (connected to terminals 14 and 15) independently from the first motor. The opening
0
limit switch needs to be connected to the second motor (PHEBE ULTRA BT A SQ terminals 70-16). See Fig. E ref. 2-3.
1
The second motor (if any) (connected to terminals 14 and 15) is in parallel with the main motor. The opening limit
1
switch does not need to be connected to the second motor (PHEBE ULTRA BT A SQ terminals 70-16). See Fig.H Ref. 2-3.
0
Standard operating mode.
Opens in other direction to standard operating mode.
0
1
ATTENTION: with the Opening direction reversal logic active, the active motor 1 logic is activated
automatically.
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2.
0
9*
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the movement stops.
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while closing, the
10*
movement stops.
Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the move-
11*
ment stops.
12*
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the movement stops.
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening, the
13*
movement stops.
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the move-
14*
ment stops.
Optional extras
step-by-step mov.
2 STEP
3 STEP
CLOSED
OPENS
OPENS
DURING
CLOSING
OPEN
CLOSES
CLOSES
DURING
STOP + TCA STOP + TCA
OPENING
AFTER STOP
OPENS
OPENS
VEGA - VEGA ULTRA
4 STEP
OPENS
STOPS
CLOSES
OPENS
- 39