Table des Matières

Publicité

Parameter
min.
max.
1
99
OP. F ORCE
1
99
CLS. F ORCE
15
99
OP SPEED
15
99
CL SPEED
SLOW SPEED
15
99
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
TABLE "B" - LOGIC MENU - (logic)
Logic
Definition

Motor type

MOTOR TYPE
(Set the type of motor
connected to the
board).
Automatic Closing
TCA
FAST CLS.
Fast closing
STEP-BY-STEP
Step-by-step
movement
MOVEMNT
PRE-ALARM
Pre-alarm
34 -
THALIA
INSTALLATION MANUAL
Default
Personal
Leaf force during
50
Leaf force during
50
99
Opening speed [%}
99
Closing speed [%]
25
Slow-down speed [%]
Cross out
Default
setting
used
0
 
0
 
Time
0
 
0
 
0
 
Definition
Force exerted by leaf/leaves during opening. This is the percentage of force
delivered, beyond the force stored during the autoset cycle (and subsequently
updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
opening [%]
WARNING: It affects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary (**).
Force exerted by leaf/leaves during closing. This is the percentage of
force delivered, beyond the force stored during the autoset cycle (and
subsequently updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
closing [%]
WARNING: It affects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary (**).
Percentage of maximum speed that can be reached by motor(s) during
opening. WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING: when the
display reads "SET", obstacle detection is not active.
Percentage of maximum speed that can be reached by motor(s) during
closing. WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING: when the
display reads "SET", obstacle detection is not active.
Opening and closing speed of motor(s) during slow-down stage, given as a
percentage of maximum running speed. WARNING: Once the parameter has
been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: When the display reads ""SET"", obstacle detection is not active.
0
Motors not active
1
ELI 250 BT
2
PHOBOS BT
3
IGEA BT
4
LUX BT
5
LUX G BT
6
SUB BT
0
Logic not enabled
1
Switches automatic closing on
0
Logic not enabled
1
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Inputs configured as Start E, Start I,
0
Ped operate with 4-step logic.
Inputs configured as Start E, Start I,
1
Ped operate with 3-step logic. Pulse
during closing reverses movement.
Inputs configured as Start E, Start I,
2
Ped operate with 2-step logic. Move-
ment reverses with each pulse.
0
The flashing light comes on at the same time as the motor(s) start.
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
Description
Optional extras
step-by-step mov.
2 STEP
3 STEP
CLOSED
OPENS
OPENS
DURING
CLOSING
OPEN
CLOSES
CLOSES
DURING
STOP + TCA STOP + TCA
OPENING
AFTER STOP
OPENS
OPENS
4 STEP
OPENS
STOPS
CLOSES
OPENS

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

U-link thalia pThalia

Table des Matières