Motor Type - BFT LEO C Instructions D'installation

Masquer les pouces Voir aussi pour LEO C:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
Default
 1
300
OPEN WORK. T .
 1
300
CLS WORK. T
OPEN DELAY
10
TI E
CLS DELAY
 0
10
TI E
0
120
TCA
partial
3
300
opening
0
250
Maintenance
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
TABLE "B" - LOGIC MENU - (LOGIC)
Logic
Definition

Motor type

MOTOR TYPE
Automatic Closing
TCA
Time
Fast closing
FAST CLS.
Step-by-step
STEP-BY-STEP
movement
MOVEMNT
Pre-alarm
PRE-ALARM
Deadman
HOLD-TO-RUN
Block pulses during
IBL OPEN
opening
Block pulses during
*IBL TCA
TCA
Block pulses during
IBL CLOSE
closing
INSTALLATION MANUAL
Personal
Definition
Opening operation time [s]
300
Closing operation time [s]
300
Motor 2 opening delay
1
time [s]
Motor 1 closing delay
3
time [s]
10
Automatic closing time [s]
5
Partial opening time[%]
Programming number of
operations for
0
maintenance threshold
[in hundreds]
Cross
out
Default
setting
used
102
102
103
0
0
 
1
0
0
 
1
0
1
0
 
2
0
0
 
1
0
1
0
 
2
3
0
0
 
1
0
0
 
1
0
0
 
1
Maximum motor operation time, during opening.
Set the operation time so that it's slightly longer than the complete operating cycle time.
Maximum motor operation time, during closing.
Set the operation time so that it's slightly longer than the complete operating cycle time.
The value is changed by the Autoset cycle, adapting it to the operation time
detected
Motor 2 opening delay time with respect to motor 1.
Motor 1 closing delay time with respect to motor 2.
Waiting time before automatic closing.
Partial opening time following the activation of the PED pedestrian control. It must be less
than the opening work time.
Allows you to set a number of operations after which the need for maintenance will be reported
on the AUX output configured as Maintenance or Flashing Light and Maintenance .
Single-phase motor
Three-phase motor
Logic not enabled
Switches automatic closing on
Logic not enabled
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Inputs configured as Start E, Start I,
Ped operate with 4-step logic.
Inputs configured as Start E, Start I,
Ped operate with 3-step logic. Pulse
during closing reverses movement.
Inputs configured as Start E, Start I,
Ped operate with 2-step logic. Move-
ment reverses with each pulse.
The flashing light comes on at the same time as the motor(s) start.
The flashing light comes on approx. 3 seconds before the motor(s) start.
Pulse operation.
Deadman mode.
Input 64 is configured as OPEN UP.
Input 65 is configured as CLOSE UP.
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is
switched to Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released.
Input 64 is configured as OPEN UP.
Input 65 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
Pulse operation during opening.
Deadman mode during closing.
Input 64 is configured as PULSE OPEN.
Input 65 is configured as CLOSE UP.
WARNING: safety devices are not enabled during closing.
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
Description
Optional extras
step-by-step mov.
2 STEP
3 STEP
CLOSED
OPENS
OPENS
DURING
CLOSING
OPEN
CLOSES
CLOSES
DURING
STOP + TCA STOP + TCA
OPENING
AFTER STOP
OPENS
OPENS
4 STEP
OPENS
STOPS
CLOSES
OPENS
29
LEO C-

Publicité

Table des Matières
loading

Table des Matières