16
NOTE:: Some products cannot detect ANALOG signal inputs and
the unit may power off if there is no digital audio source detected or
user action with the remote control or front panel. Analog input signal
detection is not available in all models which may cause the unit to
inadvertently power off. In this case the Off Timer should be set to
DISABLED.
• SIGNAL SENSE:
Check if an audio signal is present on the configured
Signal Sense input. The A14 monitors the data stream to determine if
there is audio. If there is no audio detected for 10 minutes, the A14 will
enter Signal Sense Power Mode. When in Signal Sense Power Mode and
the A14 detects audio on Signal Sense input, the unit will automatically
power on. To disable this function, select the OFF option which is the
factory default setting.
NOTE: Recent software versions allow the configured Signal Sense
input to be active in Standby Mode regardless of source input active
when the unit was powered off to standby. Previous version of software
required the Signal Sense configured input to be the active source when
the unit was powered off for Signal Sense to become active and monitor
the configured input for audio. For more information and details on
supported software versions and software update steps please contact
your authorized Rotel dealer.
NOTE: When the SIGNAL SENSE function is activated the A14 will
consume additional power in signal sense standby mode.
• FIXED GAIN: Configures a Fixed Volume level for a specified input. To
enable this feature, select the desired fixed volume level for AUX1, AUX2,
USB, PC-USB, Optical 1, Optical 2, Coax 1, Coax 2, or Bluetooth. When
enabled and the input with a Fixed Volume is selected, the Volume level
will immediately be set to the specified level.
Valid settings include: VARIABLE, FIXED MIN, FIXED 01-95, FIXED MAX.
• AUX1 VOL: VARIABLE (disabled) is factory default.
• AUX2 VOL: VARIABLE (disabled) is factory default.
• USB VOL: VARIABLE (disabled) is factory default.
• PC-USB VOL: VARIABLE (disabled) is factory default.
• OPT1 VOL: VARIABLE (disabled) is factory default.
• OPT2 VOL: VARIABLE (disabled) is factory default.
• COAX1 VOL: VARIABLE (disabled) is factory default.
• COAX2 VOL: VARIABLE (disabled) is factory default.
• BTOOTH VOL: VARIABLE (disabled) is factory default.
NOTE: The Volume knob on the front panel and Volume +/- buttons
on the IR remote are disabled when the volume is Fixed. To disable this
feature set the Fixed Volume level to "Variable".
• PC-USB CLASS: Change supported PC-USB Audio Class of the attached
device.
NOTE: Some computers attached to the PC-USB do not support USB
Audio Class 2.0 and do not support 32/384 audio playback. If needed
the PC-USB can be configured for USB Audio Class 1.0. Please refer
to your computer operating system for details.
• VIEW NETWORK: Shows the network connection status and to view
the network settings. To view the network settings, press the + button on
the front panel or the ENT button on the remote control. If the network is
properly configured and attached, "Connected" will be displayed. To view
additional network configuration details, including IP Address information,
press the MENU button to toggle through the settings.
• CONFIGURE NETWORK: Allows configuration of the network IP settings.
To enter the Network Configuration menu option press the + button on the
front panel or the ENT button on the remote control.
NOTE: Configuration of the network requires the use of the remote
control to enter the IP address details. This setup cannot be completed
using the front panel controls. Please ensure you have access to the
remote control before proceeding with Network Configuration.
To begin configuration of the network, press the ENT button on the remote
control and follow as below:
The A14 supports both DHCP and STATIC IP addressing. Select the desired
IP address method with the left/right arrow buttons on the remote control
and press ENT to confirm.
If DHCP is selected, the A14 will refresh the IP address after pressing the ENT
button on the remote control to confirm. The refresh process could take up
to 10 seconds. The display will indicate if the DHCP refresh was successful.
If the refresh process failed, check the network connections and try again
by pressing the ENT button on the remote control. To exit the DHCP refresh
process, press the MENU button.
If STATIC IP address mode is selected, you must configure all settings for the
network, including IP Address, Subnet Mask, Gateway and DNS Server.
Use the up/down arrow buttons on the remote control to adjust the values
and press the left/right buttons on the remote control to move to the next
section. When the proper IP information is configured press ENT to confirm.
NOTE: For more information regarding network connection please
contact your authorized Rotel dealer.
NOTE: A network connection is not required for the A14 to operate.
• S/W VERSION: This shows the current software version loaded into the
A14. The software can be updated if the A14 is properly connected to
the Internet.
• Press the "+" button on the front panel to check if a new software
version is available.
• If a new software version is available, press the "+" button on the
front panel, to begin the software update process.
• The new software will be downloaded from the Internet. The A14
will power cycle when the software update is complete.
NOTE: Do NOT power off the A14 during the software update process.
A14 Stereo Integrated Amplifier