Input Setup; A/ Time Base; B/ Input 1 Or Input 2 - Gorgy Timing LEDI Mode D'emploi

Masquer les pouces Voir aussi pour LEDI:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.2.5. Input setup

When you click on the Input button, the input configuration of the LEDI Network ITS/
DCLS/NTP Server is displayed.

a/ Time Base

Run autonomously
Check this box if you want that your LEDI Network ITS/DCLS/NTP Server run auto-
nomously, independently of the time on input. Then set the actual date like shown
below. validate your date by pressing Submit
Note: this mode is useful for client-server synchronization tests, or if
you don't have a synchronization source. However, the date is not exact,

B/ Input 1 or Input 2

Local Time on input
In some cases, the device is not synchronized on an UTC time source but on a
local time source for example. Then you need to configure the time zone from the
Greenwich Mean Time (GMT), and the Day Saving Time policy of the source.
For example in France, the local time is UTC+1 hour in winter and UTC+2 in sum-
mer. Here is the needed configuration:
Offset from UTC : +1h00
DST : European Union
If you use an UTC time source, keep the "Local time on input" checkbox unchecked.
MDE-LEDInetworkITS-server-4078V1.3
and the accuracy is not guaranteed.
4.
WEB INTERfaCE
95

Publicité

Chapitres

Table des Matières
loading

Table des Matières