Gorgy Timing LEDI Mode D'emploi page 98

Masquer les pouces Voir aussi pour LEDI:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

STaNDaRD OUTPUT CONfIGURaTION
Offset to apply to UTC time
The previous picture shows the configuration panel for an AFNOR/IRIG-B. In addition,
the description contains identification and version of the program embedded in the out-
put card (there, it's the program NTP4DCL1, version 05390).
Each output card can be configured independently through the following parameters :
Output deactivation
Except the display, all the output cards can be deactivated. The deactivation has
the following effects :
For ASCII+TOP card, the time frame is not generated and the TOP outputs are
in the open state.
For AFNOR output, the carrier is not modulated.
The ALARM output doesn't generate warning signal.
Time Zone
The "Time Zone" is a time offset that can be added or subtracted from
the time received through the NTP protocol (which is UTC time) to ge-
nerate local time. For example in France, local time is GMT + 1:00.
Day Saving Time
In addition to the Time Zone, many countries apply a Day Saving Time correction.
The year is made of two areas: in summer time, 1 hour more is added to the time
(after Time Zone correction), in winter time only the Time zone correction is applied.
Don't forget to select the appropriate country in the WEB interface.
98
Description and hardware version of the card.
Daylight Saving Time Policy
Disable the output
MDE-LEDInetworkITS-server-4078V1.3

Publicité

Chapitres

Table des Matières
loading

Table des Matières