Télécharger Imprimer la page

Beta 1899A Mode D'emploi page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
INSTRUCTIONS FOR USE
• ammonia ≤ 25%
• ethoxylated alcohol ≤ 4
• propanol ≤ 25%
• butoxyethanol ≤ 15
• sodium hydroxide ≤ 0,3%
All the stages of cleaning are shown on the displays on the front panel.
For a wide range of liquids of several brands to be used, the software provides initial settings to configure treatment according
to the operating specifications requested by the liquid manufacturer. Simple initial settings allow the various stages of cleaning,
flushing and acceleration to be configured; in addition, the cycles that are not requested by liquid manufacturers can be bypassed.
Cycle indication
CLno
Bypassing of cleaning function (CLEANING)
Waiting time adjustment following cleaning liquid
CL15
injection
Displaying, alternating with minutes, throughout
CLEA
cleaning liquid waiting time
FLno
Bypassing of flushing function (FLUSH)
Waiting time adjustment following flushing liquid
FL10
injection (FLUSH)
Displaying, alternating with minutes, throughout
FLUS
flushing liquid waiting time
ACno
Bypassing of acceleration function
AC05
Acceleration time adjustment at 2500 rpm
Displaying, alternating with minutes, throughout
ACCE
acceleration time
PURG
PURGE function, for tank emptying
Moving segments indicate that liquid is missing
---- --
in tank
- Connect the terminals of the electric cable of the machine to the vehicle's battery: hook up the black terminal to the negative
pole (-) and the red terminal to the positive pole (+).
- When the machine is turned on, the screen where the waiting time recommended by the liquid manufacturer following injection
of the cleaning liquid (Cleaner) can be set will be shown.
- Select Clno if no waiting time is required, or enter the required amount of time in minutes;
then press START.
- Set the waiting time recommended by the liquid manufacturer following injection of the flushing liquid (Flush).
- Select FLno if no waiting time is required, or enter the required amount of time in minutes;
then press START.
- Set the acceleration time recommended by the liquid manufacturer following liquid injection; select ACno if no acceleration time
is required, or enter the required amount of time in minutes;
Cycle description
Time setting
/
If, for example, value 15 is set, the waiting time
will be 15 minutes.
/
/
If, for example, value 10 is set, the waiting time
will be 10 minutes.
/
/
If, for example, value 05 is set, the vehicle will
be kept accelerated for 5 minutes.
/
/
/
EN
11

Publicité

loading