Target Audience - Emerson TESKOM Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Appliances with a NIST inlet connection may only be used with a TESCOM
EUROPE central supply hose of up to 3 m in length that is connected to the inlet
and used in configuration with a quick connector and NIST spigot nut.
The pressure regulator is not a shutoff valve.
2.2
Set-up and mode of operation
The TESCOM EUROPE ZV compressed gas regulator II is a single-stage, direct-acting,
spring-loaded pressure regulator without primary pressure compensation. A metal
membrane acts as the seal to the atmosphere. The downstream pressure is either fixed or
can be adjusted by handwheel, depending on the model.
The version with universal connector (Air/O
at the outlet.
3
aBOUT THE INSTRUCTIONS FOR USE
3.1
Scope
These instructions for use are valid for the TESCOM EUROPE ZV compressed gas regulator
II with the part number indicated on the last page of these instructions for use.
Additional instructions for use must be observed for certain versions.
3.2

Target audience

These instructions for use are intended for anyone responsible for the installation,
operation or monitoring of the above valves and fittings.
• The operator has a duty to ensure that only personnel who are familiar with
the general practice and safety measures associated with working with gases
and gas valves and fittings, as well as with the fundamental regulations with
regard to occupational safety and accident prevention, are permitted to work
on the device. These personnel must also have been taught how to handle the
pressurised device, and have read and understood the instructions for use.
The design of the appliance, the accompanying documentation and the marking
are based on the assumption that the appliance will only be installed, operated and
monitored by trained and qualified personnel and that the trained personnel are
familiar with certain general characteristics of the appliance. As such, the instructions,
warnings and safety information focus mainly on features that are particular to the
TESCOM EUROPE appliance. The accompanying documentation does not address
various general hazards and risks that should be obvious to qualified medical
personnel. These include the incorrect use of the equipment and the possible side
effects on patients in an unusual state of health.
) at the inlet is fitted with an Air connector
2
23
GB

Publicité

Table des Matières
loading

Table des Matières