Installation; Introduction - Ecler DP 300 Manuel Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2. INSTALLATION

The DP300 can be mounted in a standard 19" rack (482.6 mm) taking up one height unit
(44 mm). The plastic washers which are provided can be used to protect the unit from damage during
rack-mounting.
For professional use it is recommended to place the processor in the same rack as the power
amplifiers.
Given the small power consumption of the unit, no ventilation is required. Nevertheless, it is
advisable not to expose the unit to extreme temperatures as well as ensure a dry and dust-free operating
environment.
It is important not to place the processor next to electrical noise sources such as transformers,
voltage dimmers, motors, etc. or their mains supply cables. The metal cover of the device should never
be removed under any circumstance for that same reason.
The DP300 operates with alternate current (AC) between 90 and 264V at 47 to 63Hz. This device
features an oversized power supply which adapts itself to any mains voltage around the world, without
the need of manual adjustment.
Even though the noise produced by powering up is minimum, it is always advisable to follow this
power up sequence: signal sources, mixing unit, processor and, finally, power amplifiers. The power
down sequence must follow exactly a reverse order. By closely following this sequences, all peaks or
transients produced by switching on and off devices do not affect the next devices in the chain and, of
course, never reach the loudspeakers, which are extremely sensitive about this.

3. INTRODUCTION

DIGITAL LOUDSPEAKER SYSTEM PROCESSOR DP300
The ultimate solution for comprehensive adjustment and control of complex loudspeaker systems
with remote control using the dp:lab software. Excellent audio quality and dynamics. The DP300 uses
high quality Σ-Δ type AD/DA converters, 48kHz sampling rate and 2 x 24bit DSP processing.
Main features:
 Superb audio quality thanks to its 24-bit DSP and 48kHz sampling rate.
 2 inputs and 6 outputs. Operating modes: Mono, 2x3 way and 3x2 way.
 Selectable Crossover slopes of 6,12,18,24 or 48dB per octave and filter types: Butterworth,
Linkwitz-Riley or Bessel.
 Parametric or shelving equalizer for smooth system frequency response up to 38 bands.
 Digital gain adjustment range from -15dB to +15dB.
 Limiter and compressor. Compressor output with adjustable threshold.
 Phase Invert option per output.
 Electronically balanced inputs and outputs.
 Up to 635ms signal delay per signal path.
 60 memory bank locations for user programs. With the use of the dp:lab software included with
the DP300, virtually unlimited programs can be stored in the computer hard drive.
 3-Level Locking system. 2 protection mechanisms with password.
 2x16 character blue backlit LCD.
 MIDI and RS-232 control.
 dp:lab software for remote control and programming of all parameters of the DP300 unit.
5

Publicité

Table des Matières
loading

Table des Matières