4 OPERATION

4.4.2 Span-Compensation

Check and modify the basic setting of 20 mA. The procedure is identical to the Offset-com-
pensation. The transmitter generates 20 mA, if the ENTER key is pressed when "OFFSET"
is displayed. Correct the span value by entering the measured value if necessary.
SPAN
ENTER
ORP SIM.
ENTER
4.4.3 Redox potential-Simulation
A redox potential value can be simulated in this menu, allowing the user to test his system
without the presence of any liquid being required. The simulated value influences the current
output and the relays.
1)
ORP SIM.
ENTER
1)
ORP SIM.
ENTER
1)
The simulation remains active until the user enters another sub-menu of the test menu.
REDOX TRANSMITTER 8206
SP= 20.00
0......9
SP= 19.96
Enter the measured value
-0000 mV
Enter the redox potential value
0......9
+0150 mV
E-30-