3 INSTALLATION
3.4 Electrical wiring
8030 standard
Standard DIN43650 plug connector, PG9-
cable glands, pipe cross section max. 1.5
2
mm
, IP65 rating.
Fig. 3 .3 Type 2508 cable plug assembly
1. To open the connector remove the
screw 1.
2. Remove internal part 3 from external
part 2.
3. Connect according to above pin
assignment.
4. When re-assembling, the internal part
may be inserted into the external part 2
in 90 °-step intervals as required.
8030
1
3
2
E-9-
FLOW SENSOR TYPE 8030
3.4.1 Wiring of 8030 with coil 1
1: Not assigned
2: Pulse output
3: Pulse output
y: Not assigned
The flow sensor type 8030 with coil is
designed to be connected to a wall mounted
flow transmitter 8025 or indicator SE34
battery powered. (see fig. 3.5 and 3.7)
3.4.2 Wiring of 8030 with Hall sensor
1: L+(12...30 VDC)
2: Pulse output NPN
3: L-
y: Pulse output PNP
The flow sensor type 8030 with Hall sensor
can be connected to a remote flow
transmitter 8025 or indicator SE34 (see
fig. 3.5 and 3.7).