EB TECHNOLOGY START-S11 Mode D'emploi page 56

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

START-S11
Set
Description
up
T 01 Opening time MOT1
T 02 Closing Time MOT1
T 03 Opening time MOT2
T 04 Closing Time MOT2
T 05 Position of the slow down MOT1 opens (advanced sec)
T 06 Position of the slow down MOT2 opens (advanced sec)
T 07 Position of the slow down MOT1 closes (advanced sec)
T 08 Position of the slow down MOT2 closes (advanced sec)
T 09 Desplacement time OPENS
T 10 Desplacement time CLOSES
T 11
Pause Time for START command
T 12 Opening Time MOT1 PARTIAL OPENING
T 13 Closing Time MOT1 PARTIAL OPENING
T 14 Pause Time for PARTIAL OPENING
T 15 Pre-lighting time when the gate is closes
T 16 Pre-lighting time when the gate is open
T 17 Electrical key Lock
T18
Courtesy Light
T 19 Reversing Stroke (0 to disable)
Motor Starting MOT1 (When the motor is starting,
T 20
the obstacle detection is not activated)
Motor Starting MOT2 (When the motor is starting,
T 21
the obstacle detection is not activated)
T 22 Delayed obstacle detection in cent. sec.
Val. Accepted
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 0 to 10 s
from 0 to 10 s
from 0 to 10 s
from 0 to 255 s
from 0 to 10 s
from 0 to 10 s
from 0 to 10 s
from 5 to 200
-28-
Technical manual
Standard
Memo
15 s
15 s
15 s
15 s
2 s
2 s
3 s
3 s
2 s
2 s
10 s
8 s
8 s
10 s
2 s
2 s
2 s
120 s
0 s
2 s
2 s
0.30 s