EB TECHNOLOGY START-S11 Mode D'emploi page 48

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

START-S11
5.16
Connection of the PHOTO-B (opening and closing )
12 13 14 15 16 17 18 19 20 21 22 23 24 25
POWER SUPPLY
OF THE RECEIVER
Receiver of the
photo-beam, NC contact
5.17
Connection of a PHOTO-B with TEST
12 13 14 15 16 17 18 19 20 21 22 23 24 25
POWER SUPPLY
OF THE RECEIVER
Receiver of the
photo-beam, NC contact
The TEST of the photo-beam works only if the photo-beams are installed properly. The control unit will check
all connections before opening!
In case the photo-beam are not working properlym the control unit will lit on for 5 seconds and the gate is
not working.
To activate the TEST put 1 in the PHOTO-B:
S 23
If you want to go back to the function WITHOUT TEST, connect the photo-cells like in the Par. 5.16 and bring
0 to the set up S23 and S06 (deactivate this function only in case other inputs are under TEST).
POWER SUPPLY OF
THE TRASMITTER
POWER SUPPLY OF
THE TRASMITTER
TEST in PHOTO-B
1 - Activated
0 - Deactivated
S 06
-20-
Technical manual
The contact of the receiver
should be:
- Isolated
(isolated from tensions)
- Normally closed
If you use more photo-beams, the
!
connections should be serial.
If the input PHOTO-STOP
is not used,
put S17 in 0
28 29 30 31 32
TEST in the INPUT of the
SAfETiES
1 - Activated
0 - Deactivated

Publicité

Chapitres

Table des Matières
loading

Table des Matières