EB TECHNOLOGY START-S11 Mode D'emploi page 47

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

START-S11
5.14
Connection of the PHOTO A 24 Vac (only when closing)
12 13 14 15 16 17 18 19 20 21 22 23 24 25
POWER SUPPLY
OF THE RECEIVER
Receiver of the
photo-beam, NC contact
5.15
Connection of the PhOTO A (activated when closing) with TEST
12 13 14 15 16 17 18 19 20 21 22 23 24 25
POWER SUPPLY
OF THE RECEIVER
Receiver of the
photo-beam, NC contact
The TEST of the photo-beam works only if the photo-beams are installed properly. The control unit will check
all connections before opening!
In case the photo-beam are not working properlym the control unit will lit on for 5 seconds and the gate is
not working.
To activate the TEST put 1 in the PHOTO-A:
S 22
If you want to go back to the function WITHOUT TEST, connect the photo-cells like in the Par. 5.14 and bring
0 to the set up S22 and S06 (deactivate this function only in case other inputs are under TEST).
POWER SUPPLY OF
THE TRASMITTER
POWER SUPPLY OF
THE TRASMITTER
TEST in PHOTO-A
1 - Activated
0 - Deactivated
S 06
-19-
Technical manual
The contact of the receiver
should be:
- Isolated
(isolated from tensions)
- Normally closed
If you use more photo-beams, the
!
connections should be serial.
If the input PHOTO A
is not used,
put S16 in 0
28 29 30 31 32
TEST in the INPUT of the
SAfETiES
1 - Activated
0 - Deactivated