8
Remote Controls MANAGING
This receiver can manage standard codes from 12 till 64 bit and rolling codes HCS©. The fi rst learned trans-
mitter establish the code's type taht the receiver has to manage, it means that the transmitter has to have the
same code's type. Concerning the rolling codes it is possible to activate or disactivate the key'scontrol and
the rolling counter. With this function you can choose the security level of the receiver.
8.1
CANCELLATION of the MEMORY CODE
This operation cancel all codes previously memorized. If you need to cancel one single code, see next chap-
ter. The cancellation of the memory is possible only when the gate is CLOSED.
!
we recommend to cancel the memory before the memorization
of the fi rst remote control, this to be sure that no other codes are inside.
c 03
1
2
P110
3
----
4
8.2
ROLLING CODE activated
If you bring S08 on 1, the control unit will accept
only HCS codes and it will control the rolling code
counter. The remote controls cannot be copied. If
the rolling code counter is not activated, it will ac-
cepted only the fi xed part of the code.
With buttons P1, P2 and P3
go to the function C03.
Press P1 to confi rm
P1 confi rm
To cancel the operation press P1 in 10 seconds againt.
Otherwise you have to wait.
Reset successfullt done!
S 08
-25-
Technical manual
ROLLING CODE
COMPLETE
1 - Activated
0 - Deactivated (Standard)